Experimental study of hybrid anti-icing systems combining thermoelectric and hydrophobic coatings

Fortin Guy, Adomou Maryelle et Perron Jean. (2011). Experimental study of hybrid anti-icing systems combining thermoelectric and hydrophobic coatings. SAE Technical Papers, 380003,

[thumbnail of Experimental Study of Hybrid Anti-Icing systems combining thermoelectric and hydrophobic coatings.pdf] PDF
Administrateurs seulement

659kB

URL officielle: http://dx.doi.org/doi:10.4271/2011-38-0003

Résumé

Two commercial hydrophobic coatings: StaClean™ with a water droplet contact angle of 101°and Wearlon® Super F1-Ice with a contact angle of 115°and one superhydrophobic coating: HIREC 1450 with a contact angle of 152° were studied combined with a thermoelectric anti-icing system under icing conditions. All coatings and the reference surface were tested under glaze and rime ice. The deicing tests were conducted in the Anti-icing Materials International Laboratory's (AMIL) low speed closed loop Icing Wind Tunnel with 0.4 g/m3 liquid water content, a 26.7 ± 2.6 μm water droplet median volumetric diameter, 21 ± 0.5 m/s air speed and temperatures of -5 and -20 ± 0.5°C. For these tests, a 4′ chord NACA 63-415 airfoil 2D blade box-section of 10′ covered with a thin aluminum sheet protected at the leading edge and on the bottom by a thermoelectric anti-icing system composed of two ′ × 10′ heating elements with a power density of 40 W/in2, was used. The superhydrophobic coating showed excellent results with a power reduction of 13% for rime ice and 33% for glaze ice. Hydrophobic coatings performed at a lower level than the superhydrophobic coatings with a power reduction of about 8% for rime ice and 13% for glaze ice, but their effect was still significant. Also, the coatings significantly improved the runback water, most probably due to their hydrophobic nature. For the superhydrophobic coating, the surface was mostly free of ice due to the fact that drops roll over the surface to the trailing edge and for hydrophobic coatings, the runback back water froze outside the protected area; with time, a barrier developed which stopped runback water and ice accumulation increased with time. For rime and glaze ice accretion, the higher the contact angle, the more effective the coating; which suggests that a superhydrophobic surface with a high contact angle could significantly reduce the anti-icing power required.

Type de document:Article publié dans une revue avec comité d'évaluation
Volume:380003
Version évaluée par les pairs:Oui
Date:2011
Sujets:Sciences naturelles et génie > Génie > Génie des matériaux et génie métallurgique
Département, module, service et unité de recherche:Départements et modules > Département des sciences appliquées > Module d'ingénierie
Mots-clés:Etude expérimentale, systèmes anti-givrage hybrides, revêtements thermoélectriques, revêtements hydrophobes
Déposé le:22 déc. 2015 14:58
Dernière modification:09 déc. 2016 13:57
Afficher les statistiques de telechargements

Éditer le document (administrateurs uniquement)

Creative Commons LicenseSauf indication contraire, les documents archivés dans Constellation sont rendus disponibles selon les termes de la licence Creative Commons "Paternité, pas d'utilisation commerciale, pas de modification" 2.5 Canada.

Bibliothèque Paul-Émile-Boulet, UQAC
555, boulevard de l'Université
Chicoutimi (Québec)  CANADA G7H 2B1
418 545-5011, poste 5630