Constellation, le dépôt institutionnel de l'Université du Québec à Chicoutimi

Comparison and validation of pressure and acceleration time-domain waveform models of a smart insole for accurate step count in healthy people

Ngueleu Armelle-Myriane, Batcho Charles Sebiyo et Otis Martin J.-D.. (2023). Comparison and validation of pressure and acceleration time-domain waveform models of a smart insole for accurate step count in healthy people. Dans : ICBRA '22: Proceedings of the 9th International Conference on Bioinformatics Research and Applications , Septembre 2022, Berlin Germany.

[thumbnail of Comparison and validation of pressure and acceleration time-domain waveform models of a smart insole for accurate step count in healthy people.pdf] PDF - Version publiée
Administrateurs seulement

562kB

URL officielle: https://doi.org/10.1145/3569192.3569213

Résumé

Several studies have shown good accuracies for step count based on pressure signals of smart insoles in people walking at different speeds. Although smart insoles are often equipped with pressure sensors and accelerometer, no study has focused on comparing the accuracy of step count separately based on pressure and acceleration signals in healthy people. The objectives of this study were to design a waveform model of accelerometer and pressure sensors, and then compare with commercially well-known step count devices and validate these models using manual step counter for step count. Eight healthy participants (age: 39.8±17.56 years old) wore a pair of smart insoles, a GaitUp, and a StepWatchTM and performed the six-minute walking test at walking speeds from 1.62 to 2.22 m/s. Four pressure and one acceleration waveform models were designed and used for the detection of 341 to 412 steps. Accuracies ranged from 99.80%±0.60% to 99.97%±1.38% for right side, and from 99.67%±0.63% to 99.90%±0.05% for left side with pressure waveform models. In addition, the acceleration waveform model provided accuracies of 99.87%±2.49% and 99.84%±4.77% for right and left sides respectively. Step count accuracies using the GaitUp were 99.51%±2.06% for right side, and 99.51%±4.32% for left side. Finally, the StepWatchTM yielded step count accuracies of 99.31%±15.95% and 98.52%±28.06% for right and left sides respectively. These results suggested the smart insole with pressure and acceleration waveform models as more accurate than the StepWatchTM and the GaitUp for step count.

Type de document:Matériel de conférence (Non spécifié)
Date:2023
Identifiant unique:10.1145/3569192.3569213
Sujets:Sciences naturelles et génie > Génie
Sciences naturelles et génie > Génie > Génie informatique et génie logiciel
Sciences naturelles et génie > Sciences appliquées
Département, module, service et unité de recherche:Départements et modules > Département des sciences appliquées > Module d'ingénierie
Unités de recherche > Laboratoire d’automatique et de robotique interactive (LAR.i)
Liens connexes:
Mots-clés:smart insole, step count, validity, comparison, waveform models, semelle intérieure intelligente, nombre de pas, validité, comparaison, modèles de forme d'onde
Déposé le:11 févr. 2023 20:02
Dernière modification:11 févr. 2023 20:04
Afficher les statistiques de telechargements

Éditer le document (administrateurs uniquement)

Creative Commons LicenseSauf indication contraire, les documents archivés dans Constellation sont rendus disponibles selon les termes de la licence Creative Commons "Paternité, pas d'utilisation commerciale, pas de modification" 2.5 Canada.

Bibliothèque Paul-Émile-Boulet, UQAC
555, boulevard de l'Université
Chicoutimi (Québec)  CANADA G7H 2B1
418 545-5011, poste 5630