Gauthier-Turcotte Étienne, Ménard Sylvain et Fiset Mathieu. (2022). Strength and Behavior of Spruce Pine Glulam Timber Moment Connections Using Glued-In Steel Rods. Journal of Structural Engineering, 148, (12),
Prévisualisation |
PDF
- Version acceptée
Disponible sous licence Creative Commons (CC-BY 2.5). 1MB |
URL officielle: http://dx.doi.org/10.1061/%28ASCE%29ST.1943-541X.0...
Résumé
This paper presents experimental testing on glulam beam–column moment-resisting connections using glued-in rods (GiRod) and compares the results with model predictions. Three connection geometries and varying numbers of rods and member size were tested and compared. This experiment will be helpful in grounding research by bringing in new experimental results and proposing an innovative experimentation method. Experimental results showed the high efficiency of glued-in rod connections to transfer loads and bending moment between spruce pine glulam timber members. The observed limit states of the connections were failed steel rods in ductile tensile yielding or wood splitting around the anchorage installed perpendicularly to the grain in the column. It was found that the tested connections behaved as a semirigid moment-resisting connection and exhibited a ductile failure mode when wood splitting was avoided by design. Comparison of experimental results with model predictions showed good agreement, with a deviation under 15% for the moment capacity of the connection.
Type de document: | Article publié dans une revue avec comité d'évaluation |
---|---|
ISSN: | 0733-9445 |
Volume: | 148 |
Numéro: | 12 |
Version évaluée par les pairs: | Oui |
Date: | Décembre 2022 |
Identifiant unique: | 10.1061/(ASCE)ST.1943-541X.0003486 |
Sujets: | Sciences naturelles et génie > Génie Sciences naturelles et génie > Génie > Génie des matériaux et génie métallurgique Sciences naturelles et génie > Sciences appliquées |
Département, module, service et unité de recherche: | Départements et modules > Département des sciences appliquées > Module d'ingénierie |
Mots-clés: | glued-in rods (GiRod), moment-resisting connection, glulam timber, beam–column connections, stress distribution, barres collées (GiRod), assemblage résistant à la flexion, bois lamellé-collé, assemblages poutre-poteau, répartition des contraintes |
Déposé le: | 08 avr. 2023 15:57 |
---|---|
Dernière modification: | 08 avr. 2023 15:57 |
Éditer le document (administrateurs uniquement)